Delay Dip Switch Number
(in minutes) 1 2 3 4 5 6 7 8
0 Off Off Off Off Off These 3 are not used.  Changing these has no effect on the operation of the Timer.  They have been set to Off for the default setting.
1   On

 
2  
On
 
3   On On
 
4  

On  
5   On
On  
6  
On On  
7   On On On  
8  


On
9   On

On
10  
On
On
11   On On
On
12  

On On
13   On
On On
14  
On On On
15   On On On On
   


 
0.5 On


 
1.5 On On

 
2.5 On
On
 
3.5 On On On
 
4.5 On

On  
5.5 On On
On  
6.5 On
On On  
7.5 On On On On  
8.5 On


On
9.5 On On

On
10.5 On
On
On
11.5 On On On
On
12.5 On

On On
13.5 On On
On On
14.5 On
On On On
15.5 On On On On On









Note 1 - For dip switch setting 0 delay (all off) the pumping motor activation follows the momentary actuation of the pushbutton.
Note 2 - Changing the dip switch settings after an activation has occurred will deactivate the pumping of the motor.  Pressing the pushbutton a second time after a timed activation will also deactivate the pumping of the motor.
Note 3 - When the key switch is in the off position the controller is not powered.
Note 4 - An Emergency Cutoff Switch (ECS) has been provided.  It is a series switch in between the control relay and the actual motor used for pumping.  During normal use this switch will remain in the ON position.