Delay |
Dip
Switch Number |
(in minutes) |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
0 |
Off |
Off |
Off |
Off |
Off |
These 3 are not used. Changing
these has no effect on the operation of the Timer.
They have been set to Off for the default setting. |
1 |
|
On |
|
|
|
2 |
|
|
On |
|
|
3 |
|
On |
On |
|
|
4 |
|
|
|
On |
|
5 |
|
On |
|
On |
|
6 |
|
|
On |
On |
|
7 |
|
On |
On |
On |
|
8 |
|
|
|
|
On |
9 |
|
On |
|
|
On |
10 |
|
|
On |
|
On |
11 |
|
On |
On |
|
On |
12 |
|
|
|
On |
On |
13 |
|
On |
|
On |
On |
14 |
|
|
On |
On |
On |
15 |
|
On |
On |
On |
On |
|
|
|
|
|
|
0.5 |
On |
|
|
|
|
1.5 |
On |
On |
|
|
|
2.5 |
On |
|
On |
|
|
3.5 |
On |
On |
On |
|
|
4.5 |
On |
|
|
On |
|
5.5 |
On |
On |
|
On |
|
6.5 |
On |
|
On |
On |
|
7.5 |
On |
On |
On |
On |
|
8.5 |
On |
|
|
|
On |
9.5 |
On |
On |
|
|
On |
10.5 |
On |
|
On |
|
On |
11.5 |
On |
On |
On |
|
On |
12.5 |
On |
|
|
On |
On |
13.5 |
On |
On |
|
On |
On |
14.5 |
On |
|
On |
On |
On |
15.5 |
On |
On |
On |
On |
On |
|
|
|
|
|
|
|
|
|
Note 1 - For dip switch
setting 0 delay (all off) the pumping motor activation follows the
momentary actuation of the pushbutton. |
Note 2 - Changing the dip
switch settings after an activation has occurred will deactivate the
pumping of the motor. Pressing the
pushbutton a second time after a timed activation will also deactivate
the pumping of the motor. |
Note 3 - When the key
switch is in the off position the controller is not powered. |
Note 4 - An Emergency
Cutoff Switch (ECS) has been provided. It
is a series switch in between the control relay and the actual motor
used for pumping. During normal use this
switch will remain in the ON position. |